Journal of Southern Medical University ›› 2025, Vol. 45 ›› Issue (6): 1113-1121.doi: 10.12122/j.issn.1673-4254.2025.06.01
Hongyang LI(), Wenxiong LIAO, Peng LEI, Chunyuan YANG, Yanying LI, Liping XUE, Duo TAN, Sijing LIU, Yi WU(
), Meilan CHEN(
)
Received:
2024-08-03
Accepted:
2025-04-10
Online:
2025-06-20
Published:
2025-06-27
Contact:
Yi WU, Meilan CHEN
E-mail:362342650@qq.com;13332877439@189.com;13332877439@189.cn;meilanchen918@163.com
Supported by:
Hongyang LI, Wenxiong LIAO, Peng LEI, Chunyuan YANG, Yanying LI, Liping XUE, Duo TAN, Sijing LIU, Yi WU, Meilan CHEN. Toric-ICL shows better predictability and efficacy than FS-LASIK for myopia correction in patients with moderate to high myopia and astigmatism[J]. Journal of Southern Medical University, 2025, 45(6): 1113-1121.
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.j-smu.com/EN/10.12122/j.issn.1673-4254.2025.06.01
Fig.1 Refractive outcomes of the patients at 6 months after the operation. A, B: Distribution of uncorrected distance visual acuity (UDVA) 6 months after operation in the two groups. C: Changes of postoperative UDVA and preoperative CDVA. D: Distribution of postoperative spherical equivalent (SE) in the two groups. E, F: Attempted SE refractive change plotted against the achieved SE refractive change.
Fig.2 Astigmatism analysis of the patients after the operation. A, B: Target-induced astigmatic change plotted against the surgery-induced astigmatic change. C: Corrective index of astigmatism is 0.8561 in FS-LASIK group and 0.7176 in T-ICL group (P<0.0001). D: Astigmatic distribution before and after operation in the two groups.
Fig.4 Changes in corneal endothelial cell density (A) and intraocular pressure (B) after the operation in the two groups. *P<0.05, **P<0.01, ***P<0.001, ****P<0.0001.
1 | Bullimore MA, Ritchey ER, Shah S, et al. The risks and benefits of myopia control [J]. Ophthalmology, 2021, 128(11): 1561-79. doi:10.1016/j.ophtha.2021.04.032 |
2 | Tran D, Heinrich C, Ali SF. The myopia epidemic: treatment options in the pediatric population [J]. Int Ophthalmol Clin, 2022, 62(1): 231-40. doi:10.1097/iio.0000000000000404 |
3 | Sugar A, Hood CT, Mian SI. Patient-reported outcomes following LASIK: quality of life in the PROWL studies [J]. JAMA, 2017, 317(2): 204-5. doi:10.1001/jama.2016.19323 |
4 | Kim TI, Alió Del Barrio JL, Wilkins M, et al. Refractive surgery [J]. Lancet, 2019, 393(10185): 2085-98. doi:10.1016/s0140-6736(18)33209-4 |
5 | Ganesh S, Brar S, Pawar A. Matched population comparison of visual outcomes and patient satisfaction between 3 modalities for the correction of low to moderate myopic astigmatism [J]. Clin Ophthalmol, 2017, 11: 1253-63. doi:10.2147/OPTH.S127101 |
6 | Guell JL, Morral M, Kook D, et al. Phakic intraocular lenses part 1: historical overview, current models, selection criteria, and surgical techniques [J]. J Cataract Refract Surg, 2010, 36(11): 1976-93. doi:10.1016/j.jcrs.2010.08.014 |
7 | Nagy ZZ. New technology update: femtosecond laser in cataract surgery [J]. Clin Ophthalmol, 2014, 8: 1157-67. doi:10.2147/opth.s36040 |
8 | Ang M, Gatinel D, Reinstein DZ, et al. Refractive surgery beyond 2020 [J]. Eye (Lond), 2021, 35(2): 362-82. doi:10.1038/s41433-020-1096-5 |
9 | Chang JS, Meau AY. Visian Collamer phakic intraocular lens in high myopic Asian eyes [J]. J Refract Surg, 2007, 23(1): 17-25. doi:10.3928/1081-597x-20070101-05 |
10 | Price MO, Price FW. Evaluation of the toric implantable collamer lens for simultaneous treatment of myopia and astigmatism [J]. Expert Rev Med Devices, 2015, 12(1): 25-39. doi:10.1586/17434440.2015.984685 |
11 | Nakamura T, Isogai N, Kojima T, et al. Posterior chamber phakic intraocular lens implantation for the correction of myopia and myopic astigmatism: a retrospective 10-year follow-up study [J]. Am J Ophthalmol, 2019, 206: 1-10. doi:10.1016/j.ajo.2019.04.024 |
12 | Alfonso JF, Baamonde B, Madrid-Costa D, et al. Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatism [J]. J Cataract Refract Surg, 2010, 36(8): 1349-57. doi:10.1016/j.jcrs.2010.02.022 |
13 | Read SA, Collins MJ, Carney LG. A review of astigmatism and its possible genesis [J]. Clin Exp Optom, 2007, 90(1): 5-19. doi:10.1111/j.1444-0938.2007.00112.x |
14 | Alpins NA. New method of targeting vectors to treat astigmatism [J]. J Cataract Refract Surg, 1997, 23(1): 65-75. doi:10.1016/s0886-3350(97)80153-8 |
15 | Alpins N. Astigmatism analysis by the Alpins method [J]. J Cataract Refract Surg, 2001, 27(1): 31-49. doi:10.1016/s0886-3350(00)00798-7 |
16 | Alpins NA. A new method of analyzing vectors for changes in astigmatism [J]. J Cataract Refract Surg, 1993, 19(4): 524-33. doi:10.1016/s0886-3350(13)80617-7 |
17 | Abulafia A, Koch DD, Holladay JT, et al. Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: suggested terminology, analysis, and standards for outcome reports [J]. J Cataract Refract Surg, 2018, 44(10): 1169-74. doi:10.1016/j.jcrs.2018.07.027 |
18 | Chen X, Shen Y, Xu H, et al. One-year natural course of corneal densitometry in high myopic patients after implantation of an implantable collamer lens (model V4c) [J]. BMC Ophthalmol, 2020, 20(1): 50. doi:10.1186/s12886-020-1320-x |
19 | Chen K, Hu Z, Zhou J, et al. Vector analysis of the effects of FS-LASIK and toric ICL for moderate to high astigmatism correction [J]. J Ophthalmol, 2018, 2018: 6952710. doi:10.1155/2018/6952710 |
20 | Shen Y, Chen X, Xian Y, et al. Safety of intraocular pressure measurement using air-puff tonometer after implantable collamer lens implantation [J]. J Cataract Refract Surg, 2022, 48(8): 900-5. doi:10.1097/j.jcrs.0000000000000886 |
21 | Moshirfar M, Bundogji N, Tukan AN, et al. Toric implantable collamer lens for the treatment of myopic astigmatism [J]. Clin Ophthalmol, 2021, 15: 2893-906. doi:10.2147/opth.s321095 |
22 | Santhiago MR, Kara-Junior N, Waring GOT. Microkeratome versus femtosecond flaps: accuracy and complications [J]. Curr Opin Ophthalmol, 2014, 25(4): 270-4. doi:10.1097/icu.0000000000000070 |
23 | Reinstein DZ, Archer TJ, Gobbe M. Accuracy and reproducibility of cap thickness in small incision lenticule extraction [J]. J Refract Surg, 2013, 29(12): 810-5. doi:10.3928/1081597x-20131023-02 |
24 | Hashem AN, El Danasoury AM, Anwar HM. Axis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism [J]. J Refract Surg, 2009, 25(10 ): S939-43. doi:10.3928/1081597X-20090915-08 |
25 | Kamiya K, Shimizu K, Aizawa D, et al. One-year follow-up of posterior chamber toric phakic intraocular lens implantation for moderate to high myopic astigmatism [J]. Ophthalmology, 2010, 117(12): 2287-94. doi:10.1016/j.ophtha.2010.03.054 |
26 | Sari ES, Pinero DP, Kubaloglu A, et al. Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up [J]. Graefes Arch Clin Exp Ophthalmol, 2013, 251(5): 1413-22. doi:10.1007/s00417-012-2172-8 |
27 | Niu L, Miao H, Tian M, et al. One-year visual outcomes and optical quality of femtosecond laser small incision lenticule extraction and Visian Implantable Collamer Lens (ICL V4c) implantation for high myopia [J]. Acta Ophthalmol, 2020, 98(6): e662-e7. doi:10.1111/aos.14344 |
28 | Helmy H, Hashem O. Intraocular pressure calculation in myopic patients after laser-assisted in situ keratomileusis [J]. Clin Ophthalmol, 2020, 14: 509-16. doi:10.2147/opth.s239329 |
29 | Gelaw Y, Kollmann M, Irungu NM, et al. The influence of central corneal thickness on intraocular pressure measured by goldmann applanation tonometry among selected Ethiopian communities [J]. J Glaucoma, 2010, 19(8): 514-8. doi:10.1097/ijg.0b013e3181ca7708 |
30 | Cacho I, Sanchez-Naves J, Batres L, et al. Comparison of intraocular pressure before and after laser in situ keratomileusis refractive surgery measured with Perkins tonometry, noncontact tonometry, and transpalpebral tonometry [J]. J Ophthalmol, 2015, 2015: 683895. doi:10.1155/2015/683895 |
31 | Agudelo LM, Molina CA, Alvarez DL. Changes in intraocular pressure after laser in situ keratomileusis for myopia, hyperopia, and astigmatism [J]. J Refract Surg, 2002, 18(4): 472-4. doi:10.3928/1081-597x-20020701-11 |
32 | Yang Z, Miao N, Wang L, et al. Comparison of different correction formulas and measurement methods for the accurate determination of intraocular pressure after SMILE and FS-LASIK surgery [J]. BMC Ophthalmol, 2022, 22(1): 404. doi:10.1186/s12886-022-02620-7 |
33 | Alfonso JF, Fernández-Vega-Cueto L, Alfonso-Bartolozzi B, et al. Five-year follow-up of correction of myopia: posterior chamber phakic intraocular lens with a central port design [J]. J Refract Surg, 2019, 35(3): 169-76. doi:10.3928/1081597x-20190118-01 |
[1] | . Gene expression profiles of myopic mouse scleral fibroblasts: a bioinformatics analysis based on single-cell RNA sequencing [J]. Journal of Southern Medical University, 2021, 41(7): 1087-1092. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||