Journal of Southern Medical University ›› 2014, Vol. 34 ›› Issue (01): 84-.

Previous Articles     Next Articles

Feasibility of non-contrast enhanced magnetic resonance angiography for diagnosis of
renal artery stenosis in elderly patients

  

  • Online:2014-01-20 Published:2014-01-20

Abstract: Objective To evaluate the diagnostic efficacy of IFIR-FIESTA technique in detecting renal artery stenosis in elderly
patients. Methods Twenty-seven aged patients underwent both IFIR-FIESTA and 3D CE-MRA examinations. The imaging
quality and renal artery stenosis grades were evaluated. Kappa test was used to assess the consistency between the two
methods. With CE-MRA as the reference, the diagnostic sensitivity, specificity, accuracy, PPV and NPV for IFIR-FIESTA were
calculated in detecting renal artery stenosis. Results The images by the two methods were 100% qualified for diagnosis,
although the image quality of CE-MRA was significantly better. IFIR-FIESTA and CE-MRA showed excellent consistency in
detecting renal artery stenosis. With CE-MRA as the reference, the diagnostic sensitivity, specificity, accuracy, PPV and NPV for
IFIR-FIESTA were 97.1%, 100%, 98.1%, 100%, and 95% in detecting renal artery stenosis, respectively. Conclusion IFIR-FIESTA
is feasible as a routine examination for detecting renal artery stenosis in elderly patients.