Journal of Southern Medical University ›› 2020, Vol. 40 ›› Issue (03): 316-320.doi: 10.12122/j.issn.1673-4254.2020.03.01
Previous Articles Next Articles
Online:
Published:
Abstract: Objective To evaluate the effects of heat inactivation of blood samples at 56 ℃ for 30 min on the results of SARS-CoV-2 antibody detection using different methods. Methods This retrospective study was conducted in 11 patients with established diagnosis of COVID-19 and 10 patients with diseases other than COVID-19 in our hospital. We collected samples of serum, plasma and whole blood from each patient between February, 12 and 18, 2020, and with a double-blind design, the samples were examined for SARS-CoV-2 antibodies before and after heat inactivation at 56 ℃ for 30 min. In all the samples, the total SARS-CoV-2 antibodies were detected using immunochromatography, and the IgM antibodies were detected using fluorescence immunochromatography; the IgM and IgG antibodies in the serum and plasma samples detected with chemiluminescence immunoassay. We compared the detection results and analyzed the correlation of semi-quantitative detection results of IgM and IgG antibodies before and after heat inactivation of the samples. Results With immunochromatography, the coincidence rate of the total SARS-CoV-2 antibody detection before and after heat inactivation of the serum and plasma samples was 90.0% in COVID-19 cases and 100.0% in the negative cases, resulting in a total coincidence rate 95.2%; for the whole blood samples, the total coincidence rates of the total SARS-CoV-2 antibodies were 100.0%. For detection of IgM antibodies in the serum, plasma and whole blood samples using fluorescence immunochromatography, the coincidence rates in SARS-CoV-2-positive and negative cases and the total coincidence rate before and after inactivation were 100.0%, 0 and 47.6% , respectively. For detection of serum IgM and IgG antibodies and plasma IgG antibodies with chemiluminescence immunoassay, the coincidence rates in SARS-CoV-2-positive and negative cases and the total coincidence rate before and after inactivation were all 100.0%, and the total coincidence rate of plasma IgM antibodies was 95.2%. Pearson correlation analysis of the semi-quantitative results of IgM and IgG detection in the serum and plasma samples showed a correlation coefficient of 0.9999 (95%CI: 0.9998-1.000, P<0.001) between the results before and after sample inactivation. Conclusion Heat inactivation of blood samples at 56 ℃ for 30 min does not obviously affect the results of immunochromatography and chemiluminescent immunoassay for detection of SARS-COV-2 antibodies but can reduce the risk of infection for the operators. Heat-inactivated samples can not be used in fluorescence immunochromatography for SARS-CoV-2 antibody detection.
. Effect of heat inactivation of blood samples on the efficacy of three detection methods of SARS-CoV-2 antibodies[J]. Journal of Southern Medical University, 2020, 40(03): 316-320.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.j-smu.com/EN/10.12122/j.issn.1673-4254.2020.03.01
https://www.j-smu.com/EN/Y2020/V40/I03/316