南方医科大学学报 ›› 2015, Vol. 35 ›› Issue (02): 288-.

• • 上一篇    下一篇

国产内镜吻合器在腹腔镜辅助直肠癌根治术中的应用

戎祯祥,张少凌,管建松   

  • 出版日期:2015-02-20 发布日期:2015-02-20

Application of domestically made endoscopic stapling instrument for laparoscopic
assisted rectal cancer resection

  • Online:2015-02-20 Published:2015-02-20

摘要: 目的通过对比分析国产与进口内镜吻合器在腹腔镜辅助直肠癌根治(Dixon)术中的应用效果,探讨国产内镜吻合器的安
全性及可行性。方法收集2012年2月~2013年12月期间在本院确诊为直肠癌需行腹腔镜辅助直肠癌根治的病例64例,随机
分为研究组35例和对照组29例。术中研究组使用瑞奇外科器械(北京)有限公司生产的ENDO RLC 通用内镜直线切割吻合器
及一次性钉匣和一次性使用RCS系列端端吻合器,对照组使用强生医疗器材有限公司已广泛应用于临床的对应产品。对比分
析两组病例术中及术后情况。结果所有病例均取得了满意的治疗效果。两组间的手术时间、术中吻合成功率、术后并发症(吻
合口出血、吻合口瘘、吻合口狭窄)发生率无统计学差异(P>0.05),而研究组术中所用内镜吻合器的平均费用低于对照组
(6604.31±699.95 vs 7822.28±576.98),有明显统计学差异(P<0.05)。结论瑞奇外科器械(北京)有限公司生产的国产内镜吻合
器应用于腹腔镜辅助直肠癌根治手术中是安全、有效的,并且还可相对降低手术费用,值得临床推广应用。

Abstract: Objective To investigate the safety and feasibility of domestically made endoscopic stapling instrument in
laparoscopic assisted rectal cancer resection (Dixon). Methods Sixty-four patients with rectal cancer were randomly divided
into the research group (35 cases) to receive laparoscopic assisted rectal cancer resection using ENDO RLC general endoscopic
linear cutter and single-use loading unit and circular staplers with staples (from REACH medical equipment co.LTD) and the
control group (29 cases) to receive surgery with the corresponding products widely used (fom Johnson & Johnson Mdical
Euipment C.Ltd). The clinical data of the two groups were compared. Results Satisfactory therapeutic effects were obtained in
all the cases. The two groups showed no significant differences in the operative time, intraoperative anastomosis success rate,
or postoperative complications (anastomotic bleeding, leakage, or stricture) between the two groups (P>0.05), but the average
cost of endoscopic stapling instrument was significantly lower in the research group (6604.31±699.95 vs 7822.28±576.98 RMB
Yuan, P<0.05). Conclusion The domestic endoscopic stapling instrument is safe, effective and less costly for laparoscopic
assisted rectal cancer resection.