[1] Goulet JA, Londy F. Interlocking intrantedullary nail, an improved method of screw placemen combining image intensification and laser light[J]. Clin Orthop Relat Res, 1992, 8 (218): 199-203. [2] CatamoL, RotiniR, Rocca M, et al. Distal centering in locked intramedullary osteosynthesis of the femur [J]. Chir Organi Mov,1998, 83(4): 375-9. [3] Granhed HP. A new technique of distal screw insertion after locked nailing [J]. Acta Orthop Scand, 1998, 69 (3): 320-1. [4] 费军,杨欣建,于洪俊.交锁髓内钉在股骨胫骨干骺端骨折中的应用[J].中华创伤杂志,2003,19(1):37-9.Fei J, Yang X J, Yu HJ. Use of intramedullary interlocking nail in femoral and tibial metaphysis fractures[J]. Chin J Trauma, 2003:19(1): 37-9. [5] Schandelmaier P, Krettek C, Tscheme H. Biomechanical study of nine different tibia locking nails [J]. J Orthop Trauma, 1996, 10(1):37-44. [6] Fairbank AC, Thomas D, Cunningham B, et al. Stability of reamed and unreamed intramedullary tibia nails [J]. Injury, 2001, 26(7):483-5. [7] Dermott Mc, Halifax NS. Biomechanical testing of the locking nails principal[J]. J Orthop Trauma, 1997, 21(5): 383-4. [8] Kyle RF. Biomechanics of intramedullary fracture fixation [J].Orthopedics, 1985, 8(1): 1356-9. [9] Knothe U, Knothe Tate ML, Klaue K, et al. Development and testing of a new self-locking intramedullary nail system [J]. Injury, 2000, 31(8): 617-26. [10] Drosos G, Kameziz ZA. Initial rotational stability of distal fractures nailing without proximal locking[J]. Injury, 2001, 32(2): 137-43. [11] Robert J, Voor MJ, Verst DA, et al. Fatigue properties of a twelve-hole versus five-hole intramedullary supracondylar nail [J]. J Orthop Trauma, 1997, 11(2): 98-102. [12] Cristofolini L, Viceconti M. Mechanical validation of whole bone composite tibia models[J]. Biomechanics, 2000, 33(1): 168-73. [13] Woo, dard PL, Self J, Calhoun J, et al. The effect of implant axial and tensional stiffeners on fracture healing[J]. J Orthop Trauma, 1987,1(4): 331-40. [14] Mc Duffee LA, Stoven S. In vitro cyclic biomechanical properties of an interlocking cyanine tibia nails[J]. Vet Surg, 2000, 29(2):163-72. [15] Sukhinani HR, Holmberg DL. Ex vivo biomechanical comparison of Pin fixation technique for canine distal femoral physical fractures [J]. Vct Surg, 1997, 26(5): 398-407. [16] Gaebler C, Stanzl-Tschegg S, Laube W, et al. The fatigue strength of small diameter tibia nail [J]. Injury, 2001, 32(5): 401-5. [17] Hutson JJ, Zych GA, Cole JD, et al. Mechanical failure of intramedullary tibia nails applied without reaming [J]. Clin Orthop,1995, 7(315): 129-37. [18] Browner BD, Colton JD. Current status of locked intramedullary nailing[J]. J Orthop Trauma, 1987, 2 (1): 183-95. [19] Wang C J, Brown CJ. Intramedullary nails, one or two screws[J] ?Med Eng Phys, 2000, 22(11): 613-24. [20] Laurence M, Freeman MAR, Swanson SAV. Engineering considerations in the intemal fixation of fractures of the tibial shaft [J].JBJS [Br], 1969, 51(5): 754-68. [21] Hajek PD, Bicknell Jr HR, Bronson WE, et al. The use of one compared with two distal screws in the treatment of femoral shaft fractures with interlocking nailing[J]. JBJS, 1993, 75(4): 519-25. [22] Kyle RF. Biomechanics of intramedullary fracture fixation [J].Orthopaedics, 1985, 8(11): 1356-9. [23] Kneifel T, Buckley R. A comparison of one versus two distal locking screws in tibial fracture treated with unreamed tibial nails: a prospective randomized clinical trail[J]. Injury, 1996, 27(4): 271-3. |