南方医科大学学报 ›› 2020, Vol. 40 ›› Issue (09): 1301-1306.doi: 10.12122/j.issn.1673-4254.2020.09.12

• • 上一篇    下一篇

胶束毛细管电泳法检测IL-12的含量

包鹏举,孙 瑶,王海华,金孝岠,张根葆   

  • 出版日期:2020-09-20 发布日期:2020-09-20

Application of micellar electrokinetic capillary chromatography for identification, quantitative detection and unfolding analysis of interleukin-12

  • Online:2020-09-20 Published:2020-09-20

摘要: 目的 建立胶束毛细管电泳法鉴定白介素-12(IL-12)、检测其含量并分析IL-12去折叠的过程。方法 以50 ?m i.d.×48.5 cm未涂层毛细管为色谱分离柱,分析影响IL-12分离效果的因素并建立IL-12标准曲线;将IL-12与抗IL-12抗体混匀液在38 ℃水浴槽中孵育,40 min后在相同条件下进行毛细管电泳,将其与IL-12、抗IL-12抗体的电泳结果比较以鉴定IL-12;将IL-12与DTT在60 ℃水浴槽中孵育不同时间,并研究IL-12在不同状态下的电泳结果分析IL-12去折叠的过程。结果 建立了以含30 mmol/L十二烷基硫酸钠(SDS)的硼酸盐(pH=9.3,80 mmol/L)为缓冲液的胶束毛细管电泳在线扫集法;IL-12的峰面积与质量浓度具有良好的线性关系,线性相关系数为0.9991,线性范围为2~120 ng/L;随着IL-12与DTT孵育时间的延长,IL-12的二硫键逐渐被打开,图谱中可显示蛋白峰随之发生的变化。结论 毛细管电泳法操作简单、灵敏度高,这为今后在肿瘤等疾病中快速检测IL-12的含量以及分析其含量变化的原因提供理论依据。

关键词: 胶束毛细管电泳, 白介素-12, 二硫键

Abstract: Objective To establish a micellar electrokinetic capillary chromatography-based method for identification and quantitative detection of interleukin-12 (IL-12) and analysis of its unfolding process. Methods An uncoated fused-silica capillary (inner diameter 50 ?m) with a total length of 48.5 cm (40 cm to the detector) was used for the experiment. The factors influencing the separation efficiency of IL-12 were analyzed, and a standard curve of IL-12 concentration was established. The mixture of IL-12 and anti-IL-12 antibody was incubated in a water bath at 38 ℃ for 40 min, and capillary electrophoresis was then performed under the same conditions. The results were compared with those of IL-12 and anti-IL-12 antibody to identify IL-12. IL-12 and dithiothreitol (DTT) were incubated at 60 ℃ in water bath for different lengths of times, and the unfolding process of IL-12 was analyzed based on electrophoresis results of IL-12 in different states. Results A micellar capillary electrophoresis on-line sweep method was established with 80 mmol/L borate (pH=9.3) containing 30 mmol/L sodium dodecyl sulfate (SDS) as the buffer solution. This system showed a good linear relationship between the peak area and the mass concentration of IL-12 with a linear correlation coefficient of 0.9991 within the linear range of 2 to 120 ng/L. As the incubation time of IL-12 and DTT prolonged, the disulfide bond of IL-12 gradually opened and resulted in distinct changes in the protein peak. Conclusion This capillary electrophoresis-based method is simple and sensitive for IL-2 analysis and allows rapid detection of changes in IL-12 content in the setting of tumors and analysis of the possible causes.

Key words: micellar electrokinetic capillary chromatography, interleukin-12, disulfide bond