[1]陈林江,熊柯,吴京.光学相干断层扫描及超声生物显微镜测量眼前房深度的meta分析[J].南方医科大学学报,2013,(10):1533.
点击复制

光学相干断层扫描及超声生物显微镜测量眼前房深度的meta分析()
分享到:

《南方医科大学学报》[ISSN:/CN:]

卷:
期数:
2013年10期
页码:
1533
栏目:
出版日期:
2013-10-15

文章信息/Info

Title:
Comparison of anterior chamber depth measured by anterior segment optical coherence tomography and ultrasound biomicroscopy: a meta-analysis
作者:
陈林江熊柯吴京
关键词:
光学相干断层扫描超声生物显微镜眼前房meta分析
Keywords:
optical coherence tomography ultrasound biomicroscopy anterior chamber meta-analysis
摘要:
目的比较前节光学相干断层扫描(AS-OCT)及超生物显微镜(UBM)所测量眼前房深度结果的差异程度。方法计算机
检索相关数据库,搜集关于AS-OCT及UBM测量眼前房深度比较的研究性文献,两名评价员按照纳入排除标准独立对文献进
行筛选及质量评价,对最终纳入的文献进行Meta 分析。结果共纳入8 篇研究文献,合计710 眼,Meta 分析显示:AS-OCT及
UBM在全体人群中测得的前房深度值无统计学意义上的差异[SMD=0.19,95%置信区间为(0.00,0.39)];在原发性闭角型青光
眼患者中测得的前房深度值亦无统计学意义上的差异[SMD=0.02,95%置信区间为(-0.04,0.19)]。结论AS-OCT及UBM所测
量的前房深度不存在显著统计学差异,但由于研究文献偏少、样本量较小,致使本系统评价结果论证强度不高,还需要开展更高
质量的一致性分析。
Abstract:
Objective To compare the differences in the anterior chamber depth (ACD) measured by anterior segment optical
coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). Methods All studies pertaining to ACD measured by
AS-OCT and UBM were collected from online databases. The assessment of methodological quality and data extraction from
the included studies were performed independently by two reviewers for meta-analysis. Results Eight studies involving 710
eyes were included in the analysis. The difference of ACD measurements between AS-OCT and UBM was not statistically
significant in the overall patients included for analysis (SMD=0.19, 95% CI [0.00, 0.39]) or in the patients with primary
angle-closed glaucoma (SMD=0.02,95% CI[-0.04,0.19]). Conclusion The ACD measurements do not differ significantly
between AS-OCT and UBM. Due to the relatively small number of the included studies and the patients involved, this
conclusion needs further confirmation by high-quality studies involving larger sample sizes.

相似文献/References:

[1]张怡,姚静,王肖华,等.光学相干断层扫描诊断息肉状脉络膜血管病变的敏感性和特异性[J].南方医科大学学报,2017,(02):165.